A comparison of reading times in full-field digital mammography and digital breast tomosynthesis

Introduction

Currently, breast screening is implemented with X-ray mammography, but new technology such as digital breast tomosynthesis (DBT) may provide significant advantages because it produces three-dimensional breast images with high spatial resolution. To aid assessment of the cost-effectiveness of DBT, we have compared reading times for DBT images and full-field digital mammograms (FFDM) of the same women.

Methods

Four consultant radiologists were timed by stopwatch reading FFDM images and then DBT images, with a total of 119 timings of two view cases for each imaging modality. The mammograms used were from women recalled following a screening mammogram and from women who are screened annually due to a family history of breast cancer. The time taken to display the images and to report on them was excluded from the analysis.

Results

The reading time was significantly longer for DBT images than for FFDM images, with median times of 66 seconds and 17 seconds, respectively (P < 0.001), with times for FFDM ranging from 4.7 to 109.0 seconds and for DBT from 31.9 seconds to 180.6 seconds. The ratio of reading times DBT:FFDM was approximately 4:1, with readers varying between ratios of 2.4 to 4.9.

Conclusion

Reading times were greater for DBT as expected, since the reader has to scroll through the images slices to visualise the entire breast. The images used in this study were likely to have a higher rate of abnormalities than screening mammograms, and to have higher breast density, both of which will increase reading time over routine screening.

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Cite this article

Connor, S., Lim, Y., Tate, C. et al. A comparison of reading times in full-field digital mammography and digital breast tomosynthesis. Breast Cancer Res 14 (Suppl 1), P26 (2012). https://doi.org/10.1186/bcr3281

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/bcr3281

Keywords